30KVA Online Three Phase UPS
| Packing: | standard for export |
|---|---|
| Model NO.: | MTT series |
| Standard: | ISO9001: 2000; ISO14001: 2004 |
| Productivity: | 10k 15k 20k 30k 40k 60k 80k 100k |
| HS Code: | 85044020 |
| Trademark: | BAYKEE or OEM |
| Origin: | guangdong in china |
| Min. Order: | 5pcs |
| Transportation: | FOB shenzhen or guangzhou |
| Phase: | Three Phase |
| Protection: | Unbalanced Loads |
| Type: | On-line |
MTT series UPS (10KVA-400KVA)
Main model: MTT-10K, MTT-15K, MTT-20K, MTT-30K, MTT-40K, MTT-60K, MTT-80K, MTT-100K
30KVA Online Three Phase UPS
Three phase in and three phase out
Pure sine wave output, true on-line dual conversion design
Adopt 4 layer PCB, and SMD technology.
The sixth generation IGBT, the inverter has high efficiency, low temperature, high reliability.
Touch screen display, with the simple operation and Intuitive data, optional display language and logo.
Set the work mode on the display directly, UPS mode, ECO mode, EPS mode.
Intelligent detecting function
Excellent load feature, it is completely capable to load from 0-100% while no need to change to bypassThree phase separately control, realizes the control of instantaneous over-loading balance, so as to reach 100% unbalanced load.
Cold start
Generator compatible
RS232 and RS485 standard collocation, optional SNMP and dry contact
Perfect protection.
Selectable battery inspection module
High-powered dynamic feature
| Nominal capacity ( KVA ) | 10 KVA | 20KVA | 30 KVA | 4 0KVA | 6 0KVA | 8 0KVA | 10 0KVA | 120KVA | 150KVA | 200KVA | 300KVA | 400 KVA | ||||
| Work principle | Pure sine wave on line | |||||||||||||||
| Phase | 3phase+N+G | |||||||||||||||
| Input power factor | >0.8 , >0.95 | |||||||||||||||
| R ectifier | Nominal input voltage | 220/380VAC , 230/400VAC , 240/415VAC | ||||||||||||||
| Range | +/- 25% | |||||||||||||||
| Nominal input frequency | 50Hz +/- 10% , 60Hz +/- 10% | |||||||||||||||
| Output ripple | < 2 % | |||||||||||||||
| Soft start | 0 - 100% 5sec | |||||||||||||||
| Charge | Charge mode | constant current to constant voltage, with temp compensation; with Auto change | ||||||||||||||
| Float Voltage | 432VDC | |||||||||||||||
| Boost Voltage | 464VDC | |||||||||||||||
| Temperature compensation voltage | 3mv / degree (monomer) | |||||||||||||||
| Charge power | 20 % of Rated capacity | |||||||||||||||
| Battery | Battery Type | maintenance-free lead acid battery | ||||||||||||||
| Battery number | 32pcs 12V , or 192pcs 2V ( Nominal voltage 384VDC ) | |||||||||||||||
| Inverter | Phase | 3phase+N | ||||||||||||||
| Rated power | Rated capacity * 0.8 | |||||||||||||||
| Nominal voltage | 220/380VAC , 230/400VAC , 240/415VAC | |||||||||||||||
| Output voltage stability | +/- 1%( Stable load); +/- 3%( fluctuant load) | |||||||||||||||
| Output frequency stability | 50Hz/60Hz <+/- 0. 5% | |||||||||||||||
| C rest factor | > 3 : 1 | |||||||||||||||
| Output w aveform distortion | Sine wave ,linear load<3%;non-linear load<5% | |||||||||||||||
| Dynamic characteristics | Instant voltage< +/- 5%(from 0 to100% ), Instant recover time<10mS | |||||||||||||||
| Unbalanced load voltage | <+/- 5% | |||||||||||||||
| Overload Protection | 1 25 %10 m ; 1 50%1S ; 200 % 200 ms | |||||||||||||||
| E fficiency | >9 5 % ( full load ) | |||||||||||||||
| Bypass | Phase | 3phase+N | ||||||||||||||
| Nominal voltage | 220/380VAC , 230/400VAC , 240/415VAC | |||||||||||||||
| Transfer time | <1mS( static switch with 0 transfer time ) | |||||||||||||||
| Protection | Input protection | Input voltage/frequency over limited ; wrong phase ; lack phase protection | ||||||||||||||
| Output protection | Over current ; short circuit ; factor low protection | |||||||||||||||
| Battery protection | Over charge ; over-discharge protection | |||||||||||||||
| Temperature protection | Environment over temperature protection; inverter over temperature protection | |||||||||||||||
| Hardware failure protection | Assistant power abnormal, breaker cut off ,breaker overload, power devices over current/over voltage etc protection | |||||||||||||||
| System Parameters | Working environment | Temp: 0 -- 4 0degree , relative humidity 30% -- 90 % ( 1% decrease against 100 meters’ rise. Altitude 4000m MAX ) | ||||||||||||||
| Communication Interface | RS232, RS485; optional SNMP card(for internet long distance monitor ) | |||||||||||||||
| Redundancy function | Tandem hot backup or parallel connection | |||||||||||||||
| Dimension ( W * D * H ) mm | 430 * 750 * 10 8 0 | 4 8 0 * 89 5 * 1 200 | 98 0 * 800 * 18 0 0 | 1380 * 950 * 1800 | 160 0 * 1150 * 1800 | |||||||||||